ASTM C1399 PDF

This document describes the main differences between ASTM C and ASTM C when it comes to testing of flextural strength in fiber reinforced concrete. ASTM C determines the slow crack growth parameters of advanced fiber- reinforced concrete by using constant stress-rate flexural testing in which flexural . ASTM C Standard Test Method for Obtaining Average Residual-Strength of Fiber-Reinforced Concrete. This test method covers the determination of.

Author: Voodoole Yozshukasa
Country: Finland
Language: English (Spanish)
Genre: Software
Published (Last): 13 July 2017
Pages: 144
PDF File Size: 12.84 Mb
ePub File Size: 15.47 Mb
ISBN: 719-2-86788-777-7
Downloads: 9927
Price: Free* [*Free Regsitration Required]
Uploader: Dairg

Standards Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards.

Combining values from the two systems may result in non-conformance with the standard. You may delete a document from your Alert Profile at any time. If the document is revised or amended, you will be notified by email. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Please first log in with a verified email before subscribing to alerts. Results can be used to optimize the proportions of fiber—reinforced concrete mixtures, to determine compliance with construction specifications, to evaluate fiber—reinforced concrete which has been in service, and as a tool for research and development of fiber—reinforced concrete See Note 2.

Combining values from the two systems may result in non-conformance with the standard. Have a question about conducting the test for this standard?

ASTM C – 01 Test Method for Obtaining Average Residual-Strength of Fiber-Reinforced Concrete

The values in parentheses are for information only. It allows for comparative analysis among beams containing different fiber types, including materials, dimension and shape, and different fiber contents. Already Subscribed to this document.

  MACHIAVELLIAN MOMENT POCOCK PDF

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Link to Active This link will always route to the current Active version of the standard.

Fig. 4: ASTM C Second Loading Curves for FRC with % of Fiber A

The test provides data needed to obtain that portion of the load — deflection curve beyond which a significant amount of cracking damage has occurred and it provides a measure of satm — cracking strength, as such strength is affected by the use of fiber — reinforcement. Proceed to Checkout Continue Shopping.

Need more than one copy? The test provides data needed to obtain that portion of the load—deflection curve beyond which a significant amount of cracking xstm has occurred and it provides a measure of post—cracking strength, as such strength is affected by the use of fiber—reinforcement.

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other.

ASTM C1399 Residual Strength Fiber-Reinforced Concrete Test Equipment

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Historical Version s – view previous versions of standard. Awtm Documents purchase separately The documents listed below are referenced within the subject standard c13399 are not provided as part of the standard. Link to Active This link will always route to the current Active version of the standard.

By means of our testing expertise and modular product design, we will help find the testing solution that is right for you. When sawed beams are employed, and to avoid the effects of fiber orientation, care shall be applied to ensure that the flexural tensile surface of the beam is a sawed surface. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  JULIO BARRANCOS MOONEY OPERATORIA DENTAL PDF

You can download and open this file to your own computer but DRM prevents opening this file on another computer, including a networked server. A load rating of 10, lbf will generally be required.

E Deflectometer Deflection Gauge. This standard is not included in any packages. The average residual strength is computed using specified beam deflections that are obtained from a beam that has been cracked in a standard manner. The universal test machine must be capable of controlling the rate of motion of the loading head and meeting the requirements of Test Method ASTM C This standard does not purport to address all of the safety concerns, if any, associated with its use.

We are confident that we have what you are looking for. The test provides data needed to obtain that portion of the load-deflection curve beyond which a significant amount of cracking damage has occurred and it provides a measure of post-cracking strength, as such strength is affected by the use of fiber-reinforcement.

This standard is also available to be included in Standards Subscriptions.